RKI Instruments Oil Mist Filter, Balston 9900-05-BK, EAGLE / EAGLE 2 / Digester Gas Monitor - 33-0164RK

Price: $55.00
SKU:
33-0164RK
Model:
EAGLE
Model:
EAGLE 2
Model:
Digester Gas Monitor
Adding to cart… The item has been added

Product Overview

The RKI Instruments 33-0164RK is an oil mist removal filter. RKI identifies it as a Parker Balston 9900-05-BK disposable filter unit. The element contains an oil-soluble dye that turns red when oil reaches it, so a glance shows when oil is getting into the sample line.

In the RKI Digester Gas Monitor it is the oil mist filter in the sample flow system. RKI also lists it for EAGLE, EAGLE 2, and marine instruments.

Used On

  • RKI Digester Gas Monitor (oil mist filter, listed in the operator’s manual parts list)
  • RKI EAGLE (listed in RKI’s EAGLE replacement parts)
  • RKI EAGLE 2 and marine versions (per RKI’s part description)

Specifications

Values below are Parker’s published data for the Balston model 9900-05, grade BK.

SpecificationValue
Manufacturer partParker Balston 9900-05-BK
TypeDisposable filter unit, oil-indicating
Gas efficiency (grade BK)99.99% at 0.01 µm
Inlet / outlet1/4" tubing ports
Body materialNylon
Size1.0" dia. x 3.25" long (2.5 x 8 cm)
Maximum temperature230°F (110°C) at 0 psig
Maximum pressure125 psig at 110°F (43°C)

When to Replace

  • RKI’s Digester preventive maintenance calls for a monthly visual check of the oil mist filter, particle filter, hydrophobic filter, water trap element and dryer for dirt or particulates.
  • Replace the filter if it is dirty, if the element has turned red from oil, or if low sensor flow is traced to it.

Replacing It in the Digester Gas Monitor

  1. Turn off the monitor and its incoming power, open the door, and turn the flow regulator knob fully counterclockwise.
  2. Release the two white right-angle push fittings from the flow system and lift out the filter with the fittings still attached.
  3. Use needle-nose pliers to release the fittings from the old filter. Keep the fittings.
  4. Press the fittings onto the new filter, then push it back onto the rigid tubing. The arrow on the filter should point to the right.
  5. Restore power, confirm the PILOT light, and set the sensor flow to 3 SCFH.

Related Digester filters: particle filter 33-0167RK, hydrophobic filter 33-0171RK and water trap element 33-0413RK-02.

References

  • RKI Instruments 2026 Price List (02/17/2026)
  • RKI Digester Gas Monitor Operator’s Manual 71-0266RK (Rev. S, released 1/22/24)
  • Parker Balston Disposable Filter Units (Parker Hannifin, model 9900-05 oil-indicating DFU) and Parker Balston Disposable Filter Selection Guide

(P/N: 33-0164RK)

Reviews

​